    Biofloc reactor was used as a key unit of RAS (Recirculating Aquaculture System). The effects of different C/N on the wastewater treatment of biofloc reactor were investigated, and four different gradients of C/N ratio(DOC, Dissolved Organic Carbon; DIN, Dissolved Inorganic Nitrogen, C/N=0, 5, 10 and 15) were set. The experimental results showed that:when C/N=0 (without adding carbon source), the efficiencies of nitrogen and phosphorus removal in the reactor were not obvious, and the accumulation of NO3--N and PO43- appeared. The increase of C/N, the nitrogen and phosphorus removal efficiencies of the reactor were increasing with the rising C/N. The removal efficiency was the best when C/N=15(P < 0.05), and the removal rate (RR) of TN, NO3--N and PO43- (RR) were 46.6%, 43.49% and 24.4%, respectively. During the whole experiment, when C/N=0 and C/N=5, the removal efficiencies of SS, TAN and NO2--N were significantly higher than that of C/N=10 and C/N=15(P < 0.05). The stability of the reactor gradually became poor with the increasing C/N, and the highest C/N of reactor could be 15. When C/N was 5, the volume index of floc reactor (SVI-30) was sostenuto less than 150 mg/L, and floc expansion did not appear. When 10 ≤ C/N ≤ 15, the stability of the reactor became worse, but it had no effect on the efficiency of nitrogen and phosphorus removal in the reactor. The ORP and DO values were negatively related to the C/N of the reactor, and they can be used as the parameters of the BFT reactor to optimize the process. Overall, the BFT reactor had good water treatment efficiencies on SS, TAN and NO2--N under low C/N conditions, when C/N was more than 10, it had a good water treatment performance on TN, NO3--N and PO43-, with simultaneous nitrification and denitrification (SND) and phosphorus removal. For BFT reactor used as a key device of RAS, this study can provide reference for further research and application.

    Reference
    Related
    Cited by
Get Citation

陈伟,谭洪新,罗国芝,孙大川,刘文畅.碳氮比对生物絮凝反应器处理水质效果的影响[J].上海海洋大学学报,2018,27(6):907-915.
CHEN Wei, TAN Hongxin, LUO Guozhi, SUN Dachuan, LIU Wenchang. Effect of carbon-nitrogen ratio-nitrogen ratio(C/N) on the water quality in biofloc reactor[J]. Journal of Shanghai Ocean University,2018,27(6):907-915.

Copy
Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
History
  • Received:March 29,2018
  • Revised:May 31,2018
  • Adopted:August 02,2018
  • Online: December 03,2018
  • Published:
Article QR Code