副溶血性弧菌磁性试纸条层析体系的优化
CSTR:
作者:
作者单位:

上海海洋大学食品学院上海水产品加工及贮藏工程技术研究中心,上海海洋大学食品学院上海水产品加工及贮藏工程技术研究中心,上海海洋大学食品学院上海水产品加工及贮藏工程技术研究中心,上海海洋大学食品学院上海水产品加工及贮藏工程技术研究中心

作者简介:

通讯作者:

中图分类号:

基金项目:

上海市科技兴农重点攻关项目(沪农科攻字(2009)第6-1号,(2015)第4-5号);上海市科学技术委员会部分地方院校能力建设项目(11310501100);上海水产品加工及贮藏工程技术研究中心(11DZ2280300)


Optimization of chromatographic system of magnetic test strip for Vibrio parahaemolyticus
Author:
Affiliation:

College of Food Science & Technology, Shanghai Ocean University, Shanghai Engineering Research Center of Aquatic-Product Processing&Preservation,Shanghai,College of Food Science & Technology, Shanghai Ocean University, Shanghai Engineering Research Center of Aquatic-Product Processing&Preservation,Shanghai,College of Food Science & Technology, Shanghai Ocean University, Shanghai Engineering Research Center of Aquatic-Product Processing&Preservation,Shanghai,College of Food Science & Technology, Shanghai Ocean University, Shanghai Engineering Research Center of Aquatic-Product Processing&Preservation,Shanghai

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    为能够快速检测水产品中副溶血性弧菌(Vibrio parahaemolyticus),本研究首先制备了副溶血性弧菌多克隆抗体,然后将其标记在磁珠上形成特异性磁纳米探针,再分别以副溶血性弧菌多克隆抗体和山羊抗兔IgG作为检测线T线和质控线C线,建立了双抗夹心模式的磁性免疫层析试纸条。利用正交试验设计的方法,从Tween-20、BSA、蔗糖3种因素对层析体进行优化分析,结果表明这3个因素对层析检测的影响效果为Tween-20>BSA>蔗糖;当Tween-20含量为5%(V/V),BSA浓度为0.2 mg/mL,蔗糖浓度为0 mg/mL时,阳性信号最强,检测的准确性和灵敏度达到最优,通过单纯的肉眼观察,可在5~10 min实现1.6×104 CFU/mL 副溶血性弧菌的检测,通过T线所捕获磁信号的定量检测,可在30~40 min内实现4.1×103 CFU/mL 副溶血性弧菌的检测,为今后食源性致病菌的快速鉴定、诊断和检测提供了一种新途径。

    Abstract:

    To establish a rapid method for detection of Vibrio parahaemolyticus in aquatic products, a magnetic immunochromatographic test strip (MITS)was developed. Anti-V. parahaemolyticus polyclonal antibody (PAb) was prepared and conjugated with magnetic beads to prepare immunomagnetic beads (IMBs). Next, PAb and goat anti-rabbit IgG were used as a test line (T line) and a control line (C line) to develop a sandwich MITS. In order to improve the accuracy and sensitivity of the test strip, the concentration of surfactant, protein and saccharides in the chromatographic system was optimized by orthogonal test. Our results showed that the effect of these three factors was Tween-20>BSA>sucrose, with the optimized chromatographic system (5% Tween-20,0 mg/L sucrose,0.2 mg/mL BSA), the MITS was capable to detect 1.6×104 CFU/mL of V. parahaemolyticus in 5-10 min qualitatively and 4.1×103 CFU/mL in 30-40 min quantitatively. Our study could provide a new rapid identification, diagnosis and detection for food pathogen.

    参考文献
    相似文献
    引证文献
引用本文

刘莹莹,卢瑛,赵勇,潘迎捷.副溶血性弧菌磁性试纸条层析体系的优化[J].上海海洋大学学报,2016,25(2):298-305.
LIU Yingying, LU Ying, ZHAO Yong, PAN Yingjie. Optimization of chromatographic system of magnetic test strip for Vibrio parahaemolyticus[J]. Journal of Shanghai Ocean University,2016,25(2):298-305.

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2015-06-04
  • 最后修改日期:2015-06-15
  • 录用日期:2015-11-12
  • 在线发布日期: 2016-03-15
  • 出版日期:
文章二维码